Description

An attacker could utilize a function in MDT AutoSave versions prior to v6.02.06 that permits changing a designated path to another path and traversing the directory, allowing the replacement of an existing file with a malicious file.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Weakness enumeration

Affected software

VendorProductVersions
MDT SoftwareMDT AutoSave>= unspecified, < 6.02.06
MDT SoftwareMDT AutoSave>= 7.00, < 7.04
MDT SoftwareAutoSave for System Platform (A4SP)>= unspecified, < 4.01
MDT SoftwareA4SP5.00

References

Timeline

Published
Apr 1, 2022
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2021

CVE-2021-329507.1An out-of-bounds read issue exists within the parsing of DXF files in the Drawings SDK (All versions prior to 2022.4) resulting from the lacCVE-2021-329515.3WebAccess/NMS (Versions prior to v3.0.3_Build6299) has an improper authentication vulnerability, which may allow unauthorized users to view CVE-2021-329527.8An out-of-bounds write issue exists in the DGN file-reading procedure in the Drawings SDK (Version 2022.4 and prior) resulting from the lackCVE-2021-329539.8An attacker could utilize SQL commands to create a new user MDT AutoSave versions prior to v6.02.06 and update the user’s permissions, grantCVE-2021-329546.5Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbiCVE-2021-329559.8Delta Electronics DIAEnergie Version 1.7.5 and prior allows unrestricted file uploads, which may allow an attacker to remotely execute code.CVE-2021-329566.1Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted UCVE-2021-329577.5A function in MDT AutoSave versions prior to v6.02.06 is used to retrieve system information for a specific process, and this information coCVE-2021-329585.5Successful exploitation of this vulnerability on Claroty Secure Remote Access (SRA) Site versions 3.0 through 3.2 allows an attacker with loCVE-2021-329599.8Heap-based buffer overflow in SuiteLink server while processing commands 0x05/0x06CVE-2021-329608.8Rockwell Automation FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed contains a vulnerabilitCVE-2021-329617.5A getfile function in MDT AutoSave versions prior to v6.02.06 enables a user to supply an optional parameter, resulting in the processing of
CVE-2021-32949: High severity, CVSS 7.5 | Vulnix