CVE-2020-8470

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) server contains a vulnerable service DLL file that could allow an attacker to delete any file on the server with SYSTEM level privileges. Authentication is not required to exploit this vulnerability.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Affected software

No affected versions have been published.

Timeline

Published
Mar 18, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-84717.8For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 anCVE-2020-84727.8Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and CoCVE-2020-84737.8Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to reCVE-2020-84747.8Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control systemCVE-2020-84757.5For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 anCVE-2020-84767.5For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 anCVE-2020-84778.8The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An aCVE-2020-84783.3Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC CVE-2020-84799.8For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 anCVE-2020-84819.8For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, ControCVE-2020-84825.5Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilCVE-2020-84847.8Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacke
CVE-2020-8470: High severity, CVSS 7.5 | Vulnix