CVE-2020-16205

HighCVSS 7.2/10Last modified Jun 17, 2026

Description

Using a specially crafted URL command, a remote authenticated user can execute commands as root on the G-Cam and G-Code (Firmware Versions 1.12.0.25 and prior as well as the limited Versions 1.12.13.2 and 1.12.14.5).

Metrics

CVSS 3.1 7.2/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

VendorProductVersions
n/aG-Cam and G-CodeFirmware Versions 1.12.0.25 and prior as well as the limited Versions 1.12.13.2 and 1.12.14.5

References

Timeline

Published
Aug 14, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-162069.0The affected product is vulnerable to stored cross-site scripting, which may allow an attacker to remotely execute arbitrary code to gain acCVE-2020-162077.8Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by openiCVE-2020-162088.8The affected product is vulnerable to cross-site request forgery, which may allow an attacker to modify different configurations of a deviceCVE-2020-162099.8A malicious attacker could exploit the interface of the Fieldcomm Group HART-IP (release 1.0.0.0) by constructing messages with sufficientlyCVE-2020-16215.5A local, authenticated user with shell can obtain the hashed values of login passwords via configd traces. This issue affects all versions oCVE-2020-162109.0The affected product is vulnerable to reflected cross-site scripting, which may allow an attacker to remotely execute arbitrary code and perCVE-2020-162115.5Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. An out-of-bounds read vulnerability may be exploited by processing specially CVE-2020-162126.8In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unCVE-2020-162137.8Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user CVE-2020-162145.0In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated valCVE-2020-162157.8Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user CVE-2020-162166.5In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior
CVE-2020-16205: High severity, CVSS 7.2 | Vulnix