CVE-2020-16171

MediumCVSS 6.5/10Last modified Jun 17, 2026

Description

An issue was discovered in Acronis Cyber Backup before 12.5 Build 16342. Some API endpoints on port 9877 under /api/ams/ accept an additional custom Shard header. The value of this header is afterwards used in a separate web request issued by the application itself. This can be abused to conduct SSRF attacks against otherwise unreachable Acronis services that are bound to localhost such as the NotificationService on 127.0.0.1:30572.

Metrics

CVSS 3.1 6.5/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Sep 21, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-16186.8On Juniper Networks EX and QFX Series, an authentication bypass vulnerability may allow a user connected to the console port to login as rooCVE-2020-16196.7A privilege escalation vulnerability in Juniper Networks QFX10K Series, EX9200 Series, MX Series, and PTX Series with Next-Generation RoutinCVE-2020-161926.1LimeSurvey 4.3.2 allows reflected XSS because application/controllers/LSBaseController.php lacks code to validate parameters.CVE-2020-161935.4osTicket before 1.14.3 allows XSS because include/staff/banrule.inc.php has an unvalidated echo $info['notes'] call.CVE-2020-161945.3An Insecure Direct Object Reference (IDOR) vulnerability was found in Prestashop Opart devis < 4.0.2. Unauthenticated attackers can have accCVE-2020-161974.3An issue was discovered in Octopus Deploy 3.4. A deployment target can be configured with an Account or Certificate that is outside the scopCVE-2020-161986.3When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or iCVE-2020-161997.8Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. Multiple stack-based buffer overflow vulnerabilities may be exCVE-2020-16205.5A local, authenticated user with shell can obtain the hashed values of login passwords via configd streamer log. This issue affects all versCVE-2020-162006.5Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited CVE-2020-162013.3Delta Industrial Automation CNCSoft ScreenEditor, Versions 1.01.23 and prior. Multiple out-of-bounds read vulnerabilities may be exploited bCVE-2020-162027.8WebAccess Node (All versions prior to 9.0.1) has incorrect permissions set for resources used by specific services, which may allow code exe
CVE-2020-16171: Medium severity, CVSS 6.5 | Vulnix