CVE-2020-11999

HighCVSS 8.1/10Last modified Jun 17, 2026

Description

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.

Metrics

CVSS 3.1 8.1/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

Weakness enumeration

Affected software

VendorProductVersions
n/aFactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer softwareFactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior

References

Timeline

Published
Jun 15, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-12008.6<p>A remote code execution vulnerability exists in Microsoft SharePoint when the software fails to check the source markup of an applicationCVE-2020-120007.5The affected product is vulnerable to the handling of serialized data. The issue results from the lack of proper validation of user-suppliedCVE-2020-120019.8FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ContCVE-2020-120029.8Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple stack-based buffer overflow vulnerabilities exist caused by a lacCVE-2020-120037.5FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ContCVE-2020-120047.5The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and IgnitCVE-2020-120057.5FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ContCVE-2020-120069.8Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple relative path traversal vulnerabilities exist that may allow a loCVE-2020-120079.8A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition duCVE-2020-120087.5Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order infoCVE-2020-120097.5A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnCVE-2020-12017.8An elevation of privilege vulnerability exists in the way the Windows Now Playing Session Manager handles objects in memory, aka 'Windows No
CVE-2020-11999: High severity, CVSS 8.1 | Vulnix