CVE-2019-19551

MediumCVSS 4.8/10Last modified Jun 17, 2026

Description

In userman 13.0.76.43 through 15.0.20 in Sangoma FreePBX, XSS exists in the User Management screen of the Administrator web site. An attacker with access to the User Control Panel application can submit malicious values in some of the time/date formatting and time-zone fields. These fields are not being properly sanitized. If this is done and a user (such as an admin) visits the User Management screen and views that user's profile, the XSS payload will render and execute in the context of the victim user's account.

Metrics

CVSS 3.1 4.8/10CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Dec 6, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-195524.8In userman 13.0.76.43 through 15.0.20 in Sangoma FreePBX, XSS exists in the user management screen of the Administrator web site, i.e., the/CVE-2019-195537.5In Wireshark 3.0.0 to 3.0.6 and 2.6.0 to 2.6.12, the CMS dissector could crash. This was addressed in epan/dissectors/asn1/cms/packet-cms-teCVE-2019-195555.5read_textobject in read.c in Xfig fig2dev 3.2.7b has a stack-based buffer overflow because of an incorrect sscanf.CVE-2019-195564.6An authentication bypass in the debug interface in Mercedes-Benz HERMES 1 allows an attacker with physical access to device hardware to obtaCVE-2019-195572.4A misconfiguration in the debug interface in Mercedes-Benz HERMES 1 allows an attacker with direct physical access to device hardware to obtCVE-2019-19564.8A vulnerability in the web-based interface of the Cisco SPA112 2-Port Phone Adapter could allow an authenticated, remote attacker to conductCVE-2019-195604.6An authentication bypass in the debug interface in Mercedes-Benz HERMES 1.5 allows an attacker with physical access to device hardware to obCVE-2019-195612.4A misconfiguration in the debug interface in Mercedes-Benz HERMES 1.5 allows an attacker with direct physical access to device hardware to oCVE-2019-195624.6An authentication bypass in the debug interface in Mercedes-Benz HERMES 2.1 allows an attacker with physical access to device hardware to obCVE-2019-195632.4A misconfiguration in the debug interface in Mercedes-Benz HERMES 2.1 allows an attacker with direct physical access to device hardware to oCVE-2019-19577.5A vulnerability in the web interface of Cisco IoT Field Network Director could allow an unauthenticated, remote attacker to trigger high CPUCVE-2019-195769.8class.upload.php in verot.net class.upload before 1.0.3 and 2.x before 2.0.4, as used in the K2 extension for Joomla! and other products, om
CVE-2019-19551: Medium severity, CVSS 4.8 | Vulnix