CVE-2019-1611

MediumCVSS 6.7/10Last modified Jun 17, 2026

Description

A vulnerability in the CLI of Cisco NX-OS Software and Cisco FXOS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Firepower 4100 Series Next-Generation Firewalls are affected running software versions prior to 2.2.2.91, 2.3.1.110, and 2.4.1.222. Firepower 9300 Security Appliance are affected running software versions prior to 2.2.2.91, 2.3.1.110, and 2.4.1.222. MDS 9000 Series Multilayer Switches are affected running software versions prior to 6.2(25) and 8.3(1). Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(5). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(5). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected running software versions prior to 7.1(5)N1(1b) and 7.3(4)N1(1). Nexus 7000 and 7700 Series Switches are affected running software versions prior to 6.2(22), 7.3(3)D1(1), 8.2(3). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(5). Nexus 9500 R-Series Line Cards and Fabric Modules are affected running software versions prior to 7.0(3)F3(5).

Metrics

CVSS 3.1 6.7/10CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 11, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-161108.1The network protocol of Blade Shadow though 2.13.3 allows remote attackers to take control of a Shadow instance and execute arbitrary code bCVE-2019-161128.8TylerTech Eagle 2018.3.11 deserializes untrusted user input, resulting in remote code execution via a crafted Java object to the recorder/SeCVE-2019-161138.8Bludit 3.9.2 allows remote code execution via bl-kernel/ajax/upload-images.php because PHP code can be entered with a .jpg file name, and thCVE-2019-161149.8In ATutor 2.2.4, an unauthenticated attacker can change the application settings and force it to use his crafted database, which allows him CVE-2019-161157.8In Xpdf 4.01.01, a stack-based buffer under-read could be triggered in IdentityFunction::transform in Function.cc, used by GfxAxialShading::CVE-2019-161164.3EnterpriseDT CompleteFTP Server prior to version 12.1.3 is vulnerable to information exposure in the Bootstrap.log file. This allows an attaCVE-2019-161176.1Cross site scripting (XSS) in the photo-gallery (10Web Photo Gallery) plugin before 1.5.35 for WordPress exists via admin/models/Galleries.pCVE-2019-161186.1Cross site scripting (XSS) in the photo-gallery (10Web Photo Gallery) plugin before 1.5.35 for WordPress exists via admin/controllers/OptionCVE-2019-161199.8SQL injection in the photo-gallery (10Web Photo Gallery) plugin before 1.5.35 for WordPress exists via the admin/controllers/AlbumsgalleriesCVE-2019-16126.7A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlyCVE-2019-161208.8CSV injection in the event-tickets (Event Tickets) plugin before 4.10.7.2 for WordPress exists via the "All Post> Ticketed > Attendees" ExpoCVE-2019-161237.5In Kartatopia PilusCart 1.4.1, the parameter filename in the file catalog.php is mishandled, leading to ../ Local File Disclosure.
CVE-2019-1611: Medium severity, CVSS 6.7 | Vulnix